Technician completed heating and cooling inspection on a gas package system. Tech checked wiring, amps, and volts on unit. Pressures were also good. Carbon Monoxide tested 0 ppm. System is in good working condition.

Santa Fe, NM
11-07-2017


Installation of 4" storm collar on dryer vent. Installation of vibration pads and redwood finish under mini-split in master bedroom.

SANTA FE, NM
11-07-2017


Maintenance Contract Renew on Navien unit we installed in 2015.

SANTA FE, NM
11-07-2017


Tech made repair on duct work using sheet metal and duct sealant

SANTA FE, NM
10-31-2017


tstat not working. Found tstat went back to factory settings after replacing batteries. restarted new program to 73 all the time.

SANTA FE, NM
11-08-2017


Swamp cooler shut down

SANTA FE, NM
11-10-2017


Tech completed heating inspection on 2x carrier furnaces. Tech check wiring, volts, amps, blower motor needs to be cleaned on both systems, filers were replaced. Tech recommends motor cleaning at least one hr + new capacitors for cooling season.

SANTA FE, NM
11-09-2017


2nd inspection replaced 2x filter.

Santa Fe, NM
11-09-2017


found improper installation of Fujitsu mini splits

SANTA FE, NM
10-31-2017


Technician checked water heater for improper installation and noise issues but could not get heater to recreate noise that homeowner called about. Water heater checks out fine and tech couldnt find problem.

SANTA FE, NM
10-30-2017


Tech replaced draft inducer motor assembly and completed carbon monoixde test

SANTA FE, NM
10-27-2017


Maintenance on furnace, first payment

SANTA FE, NM
10-27-2017


Tech Completed filter on humidifier and cleaned the system from calcium

SANTA FE, NM
10-27-2017


Technician replaced boiler thermostat on Weil McLain cast iron boiler.

SANTA FE, NM
10-27-2017


Mini-split system with four heads = 240 for first and 24 for each additional head

SANTA FE, NM
10-27-2017


Dampers in return rattling - Advised to put screw in damper adjusters to hold them in place.

SANTA FE, NM
10-27-2017


tech completed maintenance on 95% XR85 TRANE. Filters were checked, cleaned, wires and amps and voltage was checked . Performed CO test, 0ppm

SANTA FE, NM
10-27-2017


Swamp cooler shut down/winterize

SANTA FE, NM
10-27-2017


toilet tank or flue valve rebuild minor standard. Flapper, float, chain, minor part.

SANTA FE, NM
11-20-2017


toilet tank or flue valve rebuild minor standard. Flapper, float, chain, minor part.

SANTA FE, NM
11-20-2017



SANTA FE, NM
01-29-2018


Standard Energy Preferred Heating and Cooling System Comfort control system Refrigerant supply system renovation Basic system code and safety upgrades

Santa Fe, NM
02-28-2019


naked system from both sides. cut hole in PVC under the sink to get snake through and found blockage to be a balloon.

SANTA FE, NM
02-05-2018


Drain the water, refill and bleed out the air Some repairs on a hydronic heating system requires the water to be removed from the system. Once repairs are made it si important that all air be removed from the system to prevent the pipes from banging and so that the radiators heat completely, otherwise the homeowner may not be comfortable.

SANTA FE, NM
01-29-2018


Tech instructed customer on how to control mini split in heat mode.

SANTA FE, NM
11-14-2017


tech performed diagnostic and maintenance check on Rinnai unit. Unit was not sending enough hot water to inside fixtures and was reset to normal operating procedures and is now delivering 120 plus hot water.

SANTA FE, NM
11-14-2017


Furnace trouble starting up- Furnace needed the doors to be put back on correctly, all vacuum ports have been cleaned, flame sensor cleaned, 20 x 25 x 1 filter repalced.

SANTA FE, NM
11-14-2017


Found gas leak. All repairs have been made with the exception of the pinhole leak @ pilot tube connection @ gas valve. needs new burner assembly, warranty parts will be located by home owner.

SANTA FE, NM
11-15-2017


tech completed boiler start up on Weil Mclain gold CGA - burner assembly is clean. Tech inspected wiring, pressures are correct, expansion tank is good. Flue vent inspect. 0ppm carbon monozide. No leaks in joints

SANTA FE, NM
11-15-2017


Tech completed heating and cooling inspection on a gas package system. tech checked wiring, amps, and volts of units. pressures were also good. carbon monoxide tested 0ppm. System is in good working order.

Santa Fe, NM
11-15-2017


returned to fix gas leak.,

SANTA FE, NM
11-15-2017


Replaced cartridges to upstairs tub

Santa Fe, NM
03-15-2019